Netcool is a leading network management solution used by organizations to monitor and manage their IT infrastructure. Known for its robust event management capabilities, Netcool helps in identifying, isolating, and resolving network issues efficiently. Its scalability and integration with various data sources make it a preferred choice for maintaining high availability and performance in complex network environments.
This article provides a curated selection of interview questions designed to test your knowledge and proficiency with Netcool. By reviewing these questions and their detailed answers, you will be better prepared to demonstrate your expertise and problem-solving abilities in a technical interview setting.
IBM Netcool/OMNIbus is a service management system that provides centralized monitoring and alerting for IT environments. Its architecture includes several components:
The ObjectServer is a core component of IBM Tivoli Netcool/OMNIbus, acting as an in-memory database that stores and processes event data. It performs several functions:
To retrieve all critical alerts from the ObjectServer, use a SQL query to select relevant columns from the alerts table, filtering results based on severity level. Alerts are typically stored in a table, with severity indicated by a column, often named Severity
.
Example SQL query:
SELECT * FROM alerts WHERE Severity = 'Critical';
In this query:
SELECT *
retrieves all columns from the alerts
table.FROM alerts
specifies the table for data retrieval.WHERE Severity = 'Critical'
filters results to include only alerts with a severity level of ‘Critical’.To automate the backup of the ObjectServer database, use a shell script with the nco_osreport
command. This command generates a report of the ObjectServer’s current state, which can be used as a backup. Schedule the script to run at regular intervals using a cron job.
Example:
#!/bin/bash # Define variables OBJECTSERVER_NAME="NCOMS" BACKUP_DIR="/path/to/backup" TIMESTAMP=$(date +%Y%m%d%H%M%S) BACKUP_FILE="${BACKUP_DIR}/objectserver_backup_${TIMESTAMP}.sql" # Create backup directory if it doesn't exist mkdir -p $BACKUP_DIR # Run the nco_osreport command to generate the backup nco_osreport -server $OBJECTSERVER_NAME -file $BACKUP_FILE # Check if the backup was successful if [ $? -eq 0 ]; then echo "Backup successful: $BACKUP_FILE" else echo "Backup failed" exit 1 fi
Triggers in Netcool automate actions when specific conditions are met, aiding in efficient network event management. They can send notifications, execute scripts, or update event statuses.
Example:
trigger 'HighSeverityAlert' { condition => sub { my $event = shift; return $event->{Severity} >= 5; }, action => sub { my $event = shift; send_notification("High severity event detected: " . $event->{Summary}); } };
In this example, a trigger named ‘HighSeverityAlert’ checks if event severity is 5 or higher. If so, it sends a notification with the event summary.
Configuring failover for the ObjectServer involves setting up a primary and backup server to ensure availability. The primary handles normal operations, while the backup takes over if the primary fails. Key steps include:
failover.dat
file to define the relationship between servers and set failover mode.Netcool Impact allows users to write policies for event correlation and automation. Correlating events based on a common attribute helps identify related incidents and reduce noise.
Example of a Netcool Impact policy correlating events by a common attribute, such as a device ID:
// Define the policy policy correlateEvents { // Define the common attribute for correlation var commonAttribute = "DeviceID"; // Fetch events with the same common attribute var events = getEventsByAttribute(commonAttribute); // Correlate events if (events.size() > 1) { // Perform correlation logic var correlatedEvent = createCorrelatedEvent(events); sendEvent(correlatedEvent); } } // Function to get events by attribute function getEventsByAttribute(attribute) { // Query to fetch events with the same attribute var query = "SELECT * FROM events WHERE " + attribute + " = ?"; return executeQuery(query); } // Function to create a correlated event function createCorrelatedEvent(events) { var correlatedEvent = new Event(); correlatedEvent.summary = "Correlated Event for " + events[0].DeviceID; correlatedEvent.severity = calculateSeverity(events); return correlatedEvent; } // Function to calculate severity function calculateSeverity(events) { // Example logic to calculate severity var maxSeverity = 0; for (var event in events) { if (event.severity > maxSeverity) { maxSeverity = event.severity; } } return maxSeverity; }
Event correlation in Netcool involves identifying and managing relationships between events to reduce noise and improve incident management efficiency. Techniques include:
Security best practices for Netcool components ensure system integrity, confidentiality, and availability. Key practices include:
To optimize ObjectServer performance in IBM Netcool, employ several strategies: